RVV-Copper core PVC insulated PVC sheathed flexible wire

RVV cable application
RVV cable is mainly used for power lines, control lines and signal transmission lines for medium and light mobile appliances, instrumentation, electronic equipment and automation devices. It can be used for anti-theft alarm systems, building intercom systems, transmission of control signals, and transmission of power. The signal is also suitable for laying in bridges and hoses.

RVV-Copper core PVC insulated PVC sheathed flexible wire
RVV-Copper core PVC insulated PVC sheathed flexible wire

Product Description

Description Copper core PVC insulated PVC sheathed flexible wire
Conductor Multi-strand copper conductor
Rated voltage 300-500V , 450/750V , 600/1000V
Insulation PVC Compound
Insulation Color Red, Blue, Grey, Yellow/Green 
Sheath PVC Compound
Sheath Color White, Black
Temperature Range -30℃~ +70℃
Number of cores 2-30 cores
Cross-sectional area 0.5-2.5mm²
Reference standards GB 5023、IEC60227、HD VDE21.5 S3
Packing specifications 100m,500m,1000m

size chart

2-core3 -core 4 -core 5 -core
0.75mm²0.75 mm² 0.75 mm² 0.75 mm²
1.0 mm² 1.0 mm² 1 mm² 1 mm²
1.5 mm² 1.5 mm² 1.5 mm² 1.5 mm²
2.5 mm² 2.5 mm² 2.5 mm² 2.5 mm²
4 mm² 4 mm² 4 mm² 4 mm²
6 mm² 6 mm² 6 mm² 6 mm²
10 mm² 10 mm² 10 mm² 10 mm²
16 mm² 16 mm² 16 mm²
25 mm² 25 mm² 25 mm²
36 mm²

light PVC sheathed soft wires size

ordinary PVC sheathed soft wires size

👉 Contact Us 👈

Leave a Comment

Choose Your Language »

light PVC sheathed soft wires 60227IEC52(RVV)300/300V

 

Nominal Area Insulate thickness Coat thickness Biggest Diameter 70℃ Least insulates resistance
mm² mm mm mm MΩ·km
2×0.5 0.5 0.6 6.0 or 3.6×6.0 0.012
2×0.75 0.5 0.6 6.4 or 9×6.4 0.01
3×0.5 0.5 0.6 6.2 0.012
3×0.75 0.5 0.6 6.8 0.01

Note: In normal use, the maximum temperature of the conductor is 70 ° C; the rated voltage is: 300 / 300V;

  1. According to the provisions of GB/T 3956-2008;
  2. The insulation material is made of PVC/D type PVC mixture;
  3. The sheath material is made of PVC/ST5 type PVC mixture;
  4. The average outer diameter should meet the requirements in the table; for circular soft wires, the insulated cores should be twisted together; for flat flexible wires, the insulated cores should be placed in parallel.

ordinary PVC sheathed soft wires 60227IEC53 (RVV)300/500V

Nominal Area Insulate thickness Coat thickness Biggest Diameter 70℃ Least insulates resistance
N×mm² mm mm mm MΩ·km
2×0.75 0.6 0.8 7.2 0.011
2×0.75 0.6 0.8 4.5×7.2 0.011
2×1.0 0.6 0.8 7.5 0.01
2×1.0 0.6 0.8 4.7×7.5 0.01
2×1.5 0.7 0.8 9 0.01
2×2.5 0.8 1 11 0.009
3×0.75 0.6 0.8 8 0.011
3×1.0 0.6 0.8 8.4 0.01
3×1.5 0.7 0.9 9.8 0.01
3×2.5 0.8 1 12 0.009
4×0.75 0.6 0.8 8.6 0.011
4×1.0 0.6 0.9 9.4 0.01
4×1.5 0.7 1 11 0.01
4×2.5 0.8 1.1 13 0.009
5×0.75 0.6 0.9 9.6 0.011
5×1.0 0.6 0.9 10 0.01
5×1.5 0.7 1.1 12 0.01
5×2.5 0.8 1.2 14 0.009

Note: In normal use, the maximum temperature of the conductor is 70 ° C; the rated voltage is: 300 / 500V;

  1. According to the provisions of GB/T 3956-2008;
  2. The insulation material is made of PVC/D type PVC mixture;
  3. The sheath material is made of PVC/ST5 type PVC mixture;
  4. The average outer diameter should meet the requirements in the table; for circular soft wires, the insulated cores should be twisted together; for flat flexible wires, the insulated cores should be placed in parallel.