TUV Solar cables are designed for connecting photovoltaic power supply systems. They are dedicated to the photovoltaic system direct current (D.C.) side with a nominal D.C. voltage of a 1.5kV. These cables can be used indoor & outdoor for flexible and fixed installations with high mechanical strength in extreme weather conditions, cables are designed to withstand the demanding environmental conditions that arise in any fixed, mobile, roof or architecturally integrated photovoltaic installation.
1 core Dimensions, Parameter
Tuv Rheinland EN50618 H1Z2Z2-K 1×1.5mm2-35mm2
Cores | Nominal Area | Strand No/Size | Conductor Straned OD. | Cable OD. | Electrical Resistance @20X) | Amp Rating 60P |
mm2 | No/Size | (mm) | (mm) | (ohm/km) | ||
1 | 1.5 | 30/0.25 | 1.58 | 4.6 | 13.7 | 30 |
1 | 2.5 | 50/0.25 | 2.02 | 5.1 | 8.21 | 42 |
1 | 4 | 56/0.29 | 2.35 | 5.5 | 5.09 | 55 |
1 | 6 | 84/0.29 | 3.2 | 6.3 | 3.39 | 70 |
1 | 10 | 142/0.3 | 4.6 | 7.8 | 1.95 | 98 |
1 | 16 | 228/0.3 | 5.6 | 9.2 | 1.24 | 132 |
1 | 25 | 361/0.3 | 6.95 | 11.3 | 0.795 | 176 |
1 | 35 | 525/0.3 | 8.3 | 13.3 | 0.565 | 218 |
1 | 50 | 720/0.3 | 9.2 | 14.8 | 0.393 | 280 |
1 | 70 | 988/0.3 | 11 | 16.9 | 0.277 | 350 |
1 | 95 | 1349/0.3 | 12.5 | 18.7 | 0.21 | 410 |
1 | 120 | 1691/0.3 | 14.2 | 20.7 | 0.164 | 480 |
Tuv Rheinland 2Pfg 1169 PV1-F 1×1.5mm2 – 35mm2
Cores | Nominal Area | Strand | Conductor Straned OD. | Cable | Electrical Resistance | Amp Rating 60t |
mm2 | No/Size | (mm) | OD.(mm) | (ohm/km) | ||
1 | 1.5 | 30/0.25 | 1.58 | 4.9 | 13.7 | 30 |
1 | 2.5 | 50/0.25 | 2.02 | 5.45 | 8.21 | 42 |
1 | 4 | 56/0.29 | 2.35 | 6.1 | 5.09 | 55 |
1 | 6 | 84/0.29 | 3.2 | 7.2 | 3.39 | 70 |
1 | 10 | 142/0.3 | 4.6 | 9 | 1.95 | 98 |
1 | 16 | 228/0.3 | 5.6 | 10.2 | 1.24 | 132 |
1 | 25 | 361/0.3 | 6.95 | 12 | 0.795 | 176 |
1 | 35 | 525/0.3 | 8.74 | 13.8 | 0.565 | 218 |
1 | 50 | 720/0.3 | 9.2 | 14.8 | 0.393 | 280 |
1 | 70 | 988/0.3 | 11 | 16.9 | 0.277 | 350 |
1 | 95 | 1349/0.3 | 12.5 | 18.7 | 0.21 | 410 |
1 | 120 | 1691/0.3 | 14.2 | 20.7 | 0.164 | 480 |
2 core Dimensions, Parameter
Tuv Rheinland EN50618 H1Z2Z2-K 2×1.5mm2-35mm2
Cores | Nominal Area | Strand | Conductor Straned OD. | Cable OD. | Electrical Resistance @ 20t> | Amp Rating 60P |
mm² | No / Size | (mm) | (mm) | (ohm/km) | ||
2 | 1.5 | 30/0.25 | 1.58 | 4.60X9.40 | 13.7 | 30 |
2 | 2.5 | 50/0.25 | 2.02 | 5.10X10.40 | 8.21 | 42 |
2 | 4 | 56/0.285 | 2.35 | 5.50X11.20 | 5.09 | 55 |
2 | 6 | 84/0.285 | 3.2 | 6.20X12.60 | 3.39 | 70 |
2 | 10 | 80/0.4 | 4.6 | 7.50X15.20 | 1.95 | 98 |
2 | 16 | 128/0.4 | 5.6 | 9.30X18.80 | 1.24 | 132 |
Tuv Rheinland 2Pfg 1169 PV – F 1×1.5mm2 – 35mm2
Cores | Nominal Area | Strand | Conductor Straned OD. | Cable OD. | Electrical Resistance @ 20t> | Amp Rating 60P |
mm² | No / Size | (mm) | (mm) | (ohm/km) | ||
2 | 1.5 | 30/0.25 | 1.58 | 4.60X9.40 | 13.7 | 30 |
2 | 2.5 | 50/0.25 | 2.02 | 5.10X10.40 | 8.21 | 42 |
2 | 4 | 56/0.285 | 2.35 | 5.50X11.20 | 5.09 | 55 |
2 | 6 | 84/0.285 | 3.2 | 6.20X12.60 | 3.39 | 70 |
2 | 10 | 80/0.4 | 4.6 | 7.50X15.20 | 1.95 | 98 |
2 | 16 | 128/0.4 | 5.6 | 9.30X18.80 | 1.24 | 132 |