LV ABC Cable

To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for PE insulated Conductors or 90°C for crosslinked polyethylene (XLPE)insulated conductors.

0.6/1KV AAAC/ACSR XLPE/PE Insulation twist cable AAAC conductor has been widely used in power transmission lines and electricity distribution lines with various voltage levels

[lgc_column grid=”50″ tablet_grid=”50″ mobile_grid=”100″ last=”false”] [/lgc_column] [lgc_column grid=”50″ tablet_grid=”50″ mobile_grid=”100″ last=”false”]

Conductor Material: Aluminium conductor

Insulation Material: PVC / PE

Name: AAAC ACSR XLPE PE Insulation ABC twist cable

Type: Low Voltage, types of wires and cables

Standard: IEC 60227

Certificate:CE/CCC/ISO

CONTACT US

[/lgc_column]

APPLICATION:

This is a kind of climate bearable PVC, HDPE and XLPE insulated aerial cables of copper core, aluminum core or aluminum alloy core, suitable for overhead power line of AC rated voltage Uo/U 0.6/1KV and below.

It is widely used in power transmission lines and electricity distribution lines with various voltage levels because they have such good characteristics as simple structure, convenient installation, and maintenance, low-cost large transmission capacity. And they are also suitable for laying across rivers valleys and the places where special geographical features exist.

STANDARD:

IEC 61089, BS 7870, DIN 48201, ASTM B399, BS EN50183, NFC33-209

CONSTRUCTION:

1.Conductor: copper, aluminum, aluminum alloy;

Insulation:PVC,HDPE,XLPE

TECHNICAL PARAMETERS:

Table 1: Technology requirements of copper core ABC insulated cable

Nominal cross section area of the conductor(mm²) Single wire Min. No of conductor Conductor O.D.(reference value)/mm Nominal thickness of insulation(mm)
10 6 3.8 1.0
16 6 4.8 1.2
25 6 6.0 1.2
35 6 7.0 1.4
50 6 8.4 1.4
70 12 10.0 1.4
95 15 11.6 1.6
120 18 13.0 1.6
150 18 14.6 1.8
185 30 16.2 2.0
240 34 18.4 2.2
The Max. Resistance of conductor at 20°C(Ω/km) The Min, resistance of insulation at rated temperature Breaking load of single core
Hard copper Soft copper 70°C 90°C Hard copper
1.906 1.83 0.0067 0.67 3471
1.198 1.15 0.0065 0.65 5486
0.749 0.727 0.0054 0.54 8465
0.540 0.524 0.0054 0.54 11731
0.399 0.387 0.0046 0.46 16502
0.276 0.268 0.0040 0.40 23461
0.199 0.193 0.0039 0.39 31759
0.158 0.153 0.0035 0.35 39911
0.128 0.124 0.0035 0.35 49505
0.1021 0.0991 0.0035 0.35 61846
0.0777 0.0754 0.0034 0.34 79823

Table 2: Technology requirements of aluminum core,aluminum alloy core ABC insulated cable

No.section area of conductor (mm²) Single wire Min. No Of conductor Conductor O.D. (reference value)/mm Cable Max. Average outer diameter(mm)
10 6 3.8 6.5
16 6 4.8 8.0
25 6 6.0 9.4
35 6 7.0 11.0
50 6 8.4 12.3
70 12 10.0 14.1
95 15 11.6 16.5
120 15 13.0 18.1
150 15 14.6 20.2
185 30 16.2 22.5
240 30 18.4 25.6
300 30 20.8 27.2
400 53 23.2 30.7
The Max. Resistance of conductor at 20°C  (Ω/km) The Min. resistance of insulation at rated temperature Breaking load of single core
Aluminum Aluminum   alloy 70°C 90°C Aluminum Aluminum   alloy
3.08 3.574 0.0067 0.67 1650 2514
1.91 2.217 0.0065 0.65 2517 4022
1.20 1.393 0.0054 0.54 3762 6284
0.868 1.007 0.0054 0.54 5177 8800
0.641 0.744 0.0046 0.46 7011 12569
0.443 0.514 0.0040 0.40 10354 17596
0.320 0.371 0.0039 0.39 13727 23880
0.253 0.294 0.0035 0.35 17339 30164
0.206 0.239 0.0035 0.35 21033 37706
0.164 0.190 0.0035 0.35 26732 46503
0.125 0.145 0.0034 0.34 34679 60329
0.100 0.116 0.0033 0.33 43349 75411
0.0778 0.0904 0.0032 0.32 55707 100548